© 1998–2003 Schneider Electric All Rights Reserved
Chapter 2—Menus VVDED397047USR6/03
7—Files Menu 06/2003
90
Table 22: 7—File Menu
Parameter Code Description
Factory
Setting
File 1 State
File 2 State
File 3 State
File 4 State
F1S
F2S
F3S
F4S
Displays the state of the corresponding file.
Possible states:
• FRE: File free
• EnG: A configuration has already been
saved in this file
FRE
FRE
FRE
FRE
NOTE: The stored
program will be
substituted for
present settings
when a file is
transferred to the
drive controller.
NOTE: Factory
default settings will
be substituted for
present settings
when Ini is
selected and
confirmed by
pressing ENT
twice when
prompted.
Parmeters LCC
and Add remain at
their previous
settings.
Operat. Type FOt
Selects a file operation. Possible operations: NO
• NO: no operation requested (default setting each time
the keypad display is reconnected to the drive
controller).
• STR: save the configuration in a keypad display file.
• REC: transfer a file to the drive controller.
• Ini: return the drive controller to the factory settings.
Password COd See “Access Code” on page 92.
Menu
7
WARNING
UNINTENDED EQUIPMENT ACTION
• Verify that the factory default or transferred file settings are compatible with the
application requirements.
• If a stored file is downloaded with the stop key disabled, this file will be transferred.
To stop the motor, an external stop command must be installed.
Failure to follow these instructions can result in death, serious injury or
equipment damage.