After the I/O have been assigned, additional parameters related to the
functions automatically appear in the menus, and the macro-
configuration is CUS: Customized. The additional parameters are listed
in Tables 17 and 18.
Table 17: New Parameters in 2—Adjust Menu After I/O
Reassignment
I/O Assignment New Parameters to Adjust
LI RP2 Ramp switching AC2 dE2
LI JOG Jog JOG JGt
LI PS4 4 preset speeds SP2 SP3
LI PS8 8 preset speeds SP4 SP5 SP6 SP7
LI DCI DC injection braking IdC
LI TL2 Second torque limit tL2
LI PR4 4 preset PID setpoints P12-P13
AI PIF PI regulator rPG rIG FbS PIC
AI SFB Tachogenerator dtS
R2 BLC Brake logic brL Ibr brt bEn
bEt Stt
R2, LO FTA Frequency threshold attained Ftd
R2, LO CTA Current threshold attained Ctd
R2, LO TSA Thermal threshold attained ttd
R2, LO F2A 2nd frequency threshold reached F2d
Table 18: Other New Parameters After I/O Reassignment
I/O Assignment Parameters to Adjust
LI -SP - Speed Str (4—Control menu)
LI FST Fast stop dCF (3—Drive menu)
LI CHP Motor switching PCC (3—Drive menu)
LI RST Fault reset rSt (6—Fault menu)
AI SFB Tachogenerator Sdd (6—Fault menu)
A+, A-, B+,
B-
RGI Summing reference PGt, PLS (3—Drive
menu)
A+, A-, B+,
B-
SAI Encoder feedback PGt, PLS (3—Drive
menu)