Functions (continued)
Altivar
®
12
variable speed drives
Factory-set drive conguration
The Altivar
®
12driveisconguredtoallowimmediatestart-upwithoutany
adjustmentforthemajorityofapplications.
Factory-setconguration:
Display: Displays the motor frequency reference
Standard motor frequency: 50 Hz
Motor supply voltage: 230 V three-phase
Acceleration and deceleration ramp times: 3 s
Low speed: 0 Hz
High speed: 50 Hz
Motorcontrolprole:Standard(voltage/frequency)
Slip compensation: 100%
Motor thermal current: Same as the nominal motor current
DCinjection:0.7xnominalmotorcurrentfor0.5s
Switching frequency: 4 kHz
Automatic adaptation of deceleration ramp
2-wire transition detection control: Logic input LI1 is assigned to forward,
logic inputs LI2, LI3 and LI4 are not assigned
Logic output LO+: Not assigned
Analog input AI1: 5 V (speed reference)
Analog output AO1: Not assigned
Fault relay R1: 1 N/O contact (R1A, R1C) which opens in the event of a fault or when
the drive is powered down
Human/Machine Interface (HMI)
Description
1 Display:
4-digit display
Display of numeric values and codes
Unit rating of displayed value
2 Display of drive status:
“REF”: Reference mode. This mode is used to display the motor frequency
reference of the active reference channel (terminals, local mode, remote display
terminal or Modbus
®
seriallink).Inlocalmode,thereferencecanbemodiedusing
the navigation button 4,ifthefunctionhasbeencongured.
“MON”: Monitoring mode. This mode is used to display the monitoring parameters.
“CONF”:Congurationmode.Thismodeisusedtocongurethedriveparameters.
It offers direct access to the “MyMenu” menu which includes the 9 most commonly
usedparametersinstandardapplications.Thislistcanbemodiedusingthe
SoMove setup software and can contain up to 25 parameters.
Allcongurableparameterscanalsobeaccessedwiththe“Full”menufor
applicationsrequiringfurtheradjustment.
3 Using the buttons:
“MODE”: Selects one of the following modes:
v “REF” reference mode
v “MON” monitoring mode
v “CONF”congurationmode
Note: This button cannot be accessed when the door on the front panel is closed.
“ESC”: Aborts a value, a parameter or a menu to return to the previous selection.
“STOP/RESET”: Controls motor stopping and drive fault clearing locally; button
activeinfactory-setconguration.
“RUN”: Controls motor operation locally, if it has been programmed as active.
4 Using the navigation button:
Rotation: Increases or decreases the parameter value, goes to the next parameter
and can also be used to switch from one mode to another.
Press: Saves the current value, selects the value.
Option of using the button as a potentiometer in local mode.
5 Protective cover which can be removed to allow access to the STOP/RESET and
RUN buttons
6 Mechanical lock for locking the door on the front panel
Introduction:
page 8
Specications:
page 10
References:
page 14
Dimensions:
page 18
Connections:
page 22
MODEMODE
MODE
REF
rEF
MON
Mon
CONF
ConF
Reference
Monitoring
parameters
Parameter
conguration
3 operating modes “REF”, “MON” and “CONF”
ATV12H075M2 with door on
front panel closed with protective
cover 5: STOP/RESET and
RUN buttons not accessible
6
4
1
5
3
2
ATV12H075M2 with door on
front panel open
3
4
5
1
2
3
ATV12H075M2 with door on front
panel closed without protective
cover 5: STOP/RESET and RUN
buttons accessible
5
4
1
3
3
2
6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Komentarze do niniejszej Instrukcji