Connections
Altivar
®
12
variable speed drives
Drives
Recommended connections
Typical connection for ATV12ppppF1, ATV12ppppM2 Typical connection for ATV12ppppM3
Single-phase power supply Three-phase power supply (power section) (1)
Negative logic (Sink) (2)
0 to 10 V
or
0-20 mA
Positive logic (Source) (2)
2
4
1
3
PC/
PA/
+
W/T3
U/T1
V/T2
AO1
COM
AI1
+
5V
R/L1
S/L2/N
R1A
R1C
R1B
COM
LI1
LI2
+
24V
U1
W1
V1
M
3
LI3
LI4
2
4
2
4
6
P1
1
3
A1
Q1Q1
5
c
b
a
LO
+
LO–
LO
+
LO–
COM
LI1
LI2
+
24V
LI3
LI4
1
3
KM1
KM1
2
4
1
6
5
3
W/T3
U/T1
V/T2
R/L1
S/L2
T/L3
U1
W1
V1
M
3
2
4
1
3
A2
6
Q1
5
2
4
Q1
1
3
6
5
(4)
Note: Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves,
uorescent lighting, etc.
Compatible components (for a complete list of references, please refer to the "Motor starter solutions - Control and protection components" and "Motor starters
up to 150 A" catalogs or visit "www.schneider-electric.us")
Item no. Description
A1 ATV12ppppF1 or ATV12ppppM2 drive (see page 14)
A2 ATV12ppppM3 drive (see page 14)
KM1 Contactor (only if a control circuit is needed; see page 24)
P1 2.2 kW reference potentiometer, SZ1 RV1202. This can be replaced by a 10 kW potentiometer (maximum).
Q1 Circuit breaker (see page 24)
Examples of recommended connections for logic and analog I/O
2-wire control 3-wire control Analog input congured
for voltage
Analog input congured for current
LI1
+
24V
LIp
ATV12pppppp
LI1: Forward
LIp: Reverse
LI1
LI2
+
24V
LIp
ATV12pppppp
LI1: Stop
LI2: Forward
LIp: Reverse
IA1
COM
+
10 V
c
b
a
2.2 kW to 10 kW
reference
potentiometer
External 10 V
ATV12pppppp
IA1
COM
0-20 mA
4-20 mA
supply
ATV12pppppp
Examples of recommended connections for logic I/O powered by an external 24 V supply (5)
Connected as positive logic (Source) Connected as negative logic (Sink)
LO
+
LO–
COM
LI1
LI2
+
24V
LI3
LI4
+
24 V
0 V
24 V
supply
COM
LI1
LI2
+
24V
LI3
LI4
+
24 V
0 V
LO
+
LO–
24 V
supply
(1) The control section is connected in exactly the same way as for the ATV12ppppF1 and ATV12ppppM2 drives.
(2) Connection as positive logic (Source) or negative logic (Sink) is congured via parameters; the factory-set conguration is positive logic (Source).
(3) Fault relay contacts for remote signalling of the drive status.
(4) The R/L1, S/L2/N and T/L3 terminals are connected at the top of the drive. The other terminals are connected on the underside of the drive.
(5) Please refer to the "Phaseo power supplies and transformers" catalog.
Introduction:
page 8
Specications:
page 10
References:
page 14
Dimensions:
page 18
Functions:
page 26
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com