The Xantrex XW System Control Panel
975-0239-01-01 5–7
This manual for use by qualified personnel only
To surface mount the Xantrex XW System Control Panel:
1. Using the supplied template sticker as a guide, mark the locations for two
mounting screws and the access hole for the network cables.
2. Using a hole saw, cut out the access hole for the network cable(s).
3. Route the network cable(s) from other Xantrex Xanbus-enabled devices
inside the wall and through the access hole.
4. Attach the mounting plate with two #6 screws.
5. Connect the network cable(s) (and terminator if necessary) to either input on
the back of the Xantrex XW System Control Panel.
Connect a network terminator to the Xantrex XW System Control Panel if it is
the last device at the end of a series-type network layout.
6. Place the unit into the mounting plate and secure it with four #6 screws.
See Figure 5-6.
7. Peel off the protective plastic coating covering the screen and indicator light.
:
CAUTION: Equipment damage
Provide adequate space within the wall for the Xantrex Xanbus cables to bend.
Do not bend the cable to one side after it leaves the Xantrex Xanbus port.
The mounting bracket itself does not provide enough space for the cables to
bend. Attempting to route the cables through the side of the mounting bracket
without providing space for the cables within the wall may results in damage to
the Xantrex XW SCP Xantrex Xanbus ports and cause network communication
problems.
Figure 5-6 Surface Mounting the Xantrex XW System Control Panel