Other versions: please consult our Customer Care Centre.
Complex, high-power machines
Drives for lifts
Type of drive
Three-phase
200...240 V
Three-phase
380...480 V
Supply voltage
Degree of protection
IP20 for unprotected drives and IP41 on the upper part
Drive Output frequency
0...599 Hz
Type of control Asynchronous motor
Flux vector control with or without sensor, voltage/frequency ratio
Synchronous motor
Vector control with and without speed feedback
Transient overtorque
220% of nominal motor torque for 2 seconds, and 170% for 60 seconds
Speed range
1…1000 in closed loop mode with encoder feedback, 1…100 in open loop mode
Functions Number of functions
> 150
Number of preset speeds
16
Number of I/O Analog inputs
2…4
Logic inputs
6…20
Analog outputs
1…3
Logic outputs
0…8
Relay outputs
2…4
Safety input
1
Dialogue
Remote graphic display terminal, SoMove setup software (1)
Communication Integrated
Modbus and CANopen
As an option
Fipio, Ethernet, Modbus Plus, P
ROFIBUS DP, DeviceNet, Uni-Telway, INTERBUS
Cards (available as an option)
Encoder interface cards, I/O extension cards, “Controller Inside” programmable card,
Encoder emulation card
Reduction of current harmonics
Integrated DC choke or supplied with the product
EMC filter Integrated
C2 EMC up to 5.5 kW
As an option
External C2 EMC from 7.5 kW
Motor power kW / HP / A
4 / 5 / 10 – ATV71LD10N4Z T4
5,5 / 7,5 / 14 – ATV71LD14N4Z T4
5,5 / 7,5 / 27 ATV71LD27M3Z T5B –
7,5 / 10 / 17 – ATV71LD17N4Z T5A
7,5 / 10 / 33 ATV71LD33M3Z T5B –
11 / 15 / 27 – ATV71LD27N4Z T5B
11 / 15 / 54 ATV71LD54M3Z T6 –
15 / 20 / 33 – ATV71LD33N4Z T5B
15 / 20 / 66 ATV71LD66M3Z T6 –
22 / 30 / 48 – ATV71LD48N4Z T7
(1) SoMove setup software : available from 2011. Altivar LIFT is also supported by Powersuite software workshop.
Dimensions (in mm) width x height x depth
without remote graphic terminal
T4 : 175 x 295 x 161 T6 : 240 x 420 x 210
T5A
: 210 x 295 x 187 T7 : 240 x 550 x 230
T5B
: 230 x 400 x 187
Altivar LIFT
4…22 kW
35