Installation Instruction 66571764GB3 Fire Detection 2
Schneider Electric Pelco Finland Oy Kalkkipellontie 6, 02650 Espoo, Finland Telephone: +358 10 446 511 Fax: +358 10 446 5103 www.pelco.com/nordic
Document Number 66571764GB3 16 2012
© 2009 Schneider Electric. All rights reserved.
Contents
1.
About this document ...........................................................................................................................................4
2. Typical placement of the units in a panel .........................................................................................................4
3. Installation, FX and FXL - control panels ....................................................................................................... 10
4. Installation, FXM - control panel ..................................................................................................................... 11
5. Installation, FXS - control panel ...................................................................................................................... 12
6. Connecting main power supply ...................................................................................................................... 13
7. Commissioning ................................................................................................................................................. 14
7.1 Necessary devices and documents ....................................................................................................... 14
7.2 Order of commissioning ......................................................................................................................... 14
8. Preliminary checks ........................................................................................................................................... 15
8.1 General ...................................................................................................................................................... 15
8.2 Preliminary checks .................................................................................................................................. 15
9. Control panel test run: Note differences with the FXS! ................................................................................ 17
9.1 Mains connection..................................................................................................................................... 17
9.2 Battery connection .................................................................................................................................. 18
10. Cable handling and preliminary measurements ....................................................................................... 19
10.1 Cable handling and measurements ....................................................................................................... 19
10.2 Cable table ................................................................................................................................................ 20
11. Addressable detector loops ....................................................................................................................... 22
11.1 Measuring the Cables .............................................................................................................................. 22
11.2 Connecting the loop to the control panel ............................................................................................. 23
11.3 Functional check of the loop .................................................................................................................. 23
12. Conventional detector lines ........................................................................................................................ 27
12.1 Measuring the Cables .............................................................................................................................. 27
12.2 Connection principles ............................................................................................................................. 28
12.2.1 Conventional line ................................................................................................................................... 28
12.2.2 Input line ................................................................................................................................................. 29
12.3 Connecting the line to the control panel ............................................................................................... 30
12.4 Functional check of the loop .................................................................................................................. 30
12.5 Compatible detectors and manual call points ...................................................................................... 31
13. Monitored output lines ................................................................................................................................ 32
13.1 Measuring the cables and connecting the end-of-line resistors ........................................................ 32
13.2 Connecting the monitored output lines to the control panel .............................................................. 33
13.3 Functional check of monitored output lines ......................................................................................... 33
14. Control outputs ............................................................................................................................................ 34
14.1 Clean relay outputs.................................................................................................................................. 34
14.2 Free power outputs.................................................................................................................................. 35
15. Signal inputs ................................................................................................................................................ 36
15.1 Connecting the inputs to the control panel .......................................................................................... 36
15.2 Testing the inputs .................................................................................................................................... 36
16. Info-line devices / connections .................................................................................................................. 37
16.1 INFO-fault messages ............................................................................................................................... 37
16.2 FMPX ......................................................................................................................................................... 37
16.3 DAPX ......................................................................................................................................................... 38
16.4 REPX and REPX-OB ................................................................................................................................ 38
16.5 MCOX and MCOX-OB .............................................................................................................................. 39
16.6 CODI / Codinet .......................................................................................................................................... 39
17. Configuration ............................................................................................................................................... 40
18. Serial communication ports ....................................................................................................................... 41
18.1 FX 3NET communication network.......................................................................................................... 42
18.2 Communication grounding ..................................................................................................................... 42
18.3 Modem connections in the communication network ........................................................................... 43
19. Alarm routing equipment ............................................................................................................................ 44
19.1 Connecting the alarm routing equipment to the control panel ........................................................... 44
20. FX, FXL and FXM connections ................................................................................................................... 45
20.1 FX and FXL panel external connections, SLC ...................................................................................... 45
Komentarze do niniejszej Instrukcji