Schneider Electric Mupgrade Utility Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Oprogramowanie Schneider Electric Mupgrade Utility. Schneider Electric Mupgrade Utility Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 130
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Conext™ Configuration

AC1AC2EventEqualizekWACharging!InvertingConext™ Configuration ToolOwner’s GuideVersion 1.00www.SEsolar.com

Strona 2 - AT WWW.SESOLAR.COM

Contentsx 975-0720-01-01This manual is for use by qualified personnel onlyGrid Tie Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 3 - About This Guide

Configuring the System Control Panel975-0720-01-01 3–35This manual is for use by qualified personnel onlyBasic ConfigurationBasic configuration includ

Strona 4 - Disclaimer

Device Configuration3–36 975-0720-01-01This manual is for use by qualified personnel onlySaving and Restoring ConfigurationsSave Configuration allows

Strona 5 - Important Safety Instructions

Configuring the Conext Battery Monitor975-0720-01-01 3–37This manual is for use by qualified personnel onlyBasic StatusThe Basic Status window shows t

Strona 6 - Safety Information

Device Configuration3–38 975-0720-01-01This manual is for use by qualified personnel onlyBattery ConfigurationBattery configuration allows you to conf

Strona 7

Configuring the Conext Battery Monitor975-0720-01-01 3–39This manual is for use by qualified personnel onlyBattery Temperature ConfigurationBattery te

Strona 8 - OPERATION

Device Configuration3–40 975-0720-01-01This manual is for use by qualified personnel onlyHardware ConfigurationHardware configuration allows you to co

Strona 9 - Contents

Configuring the Conext Battery Monitor975-0720-01-01 3–41This manual is for use by qualified personnel onlyMulti-Unit ConfigurationMulti-unit configur

Strona 10 - 4 System Logging

Device Configuration3–42 975-0720-01-01This manual is for use by qualified personnel onlyModbus ConfigurationBattery Monitor Modbus settings are confi

Strona 11 - Legacy USB-to-Xanbus Adapters

975-0720-01-01 4–1This manual is for use by qualified personnel only4 System LoggingChapter 4, “System Logging” contains information and procedures to

Strona 12 - 1 Introduction and

System Logging4–2 975-0720-01-01This manual is for use by qualified personnel onlyIntroductionWith the system logging feature you can log any paramete

Strona 13

Contents975-0720-01-01 xiThis manual is for use by qualified personnel onlyUsing the Data - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 14 - Inside the Box

Configuration975-0720-01-01 4–3This manual is for use by qualified personnel onlyConfigurationThe logging configuration is displayed as a tree. The ma

Strona 15

System Logging4–4 975-0720-01-01This manual is for use by qualified personnel onlyPolling PeriodYou can set the logging period in seconds using a drop

Strona 16

Configuration975-0720-01-01 4–5This manual is for use by qualified personnel onlyEmail OptionsOnce a log is complete, Conext Configuration Tool can au

Strona 17

System Logging4–6 975-0720-01-01This manual is for use by qualified personnel onlyTroubleshootingGetting Conext Configuration Tool to send an email ca

Strona 18

Running the Logger975-0720-01-01 4–7This manual is for use by qualified personnel onlyPassive ModeFTP normally uses two connections, one initiated fro

Strona 19

System Logging4–8 975-0720-01-01This manual is for use by qualified personnel onlyLimitationsThere is no particular limit to the number of data points

Strona 20 - OF ELECTRIC SHOCK

Using the Data975-0720-01-01 4–9This manual is for use by qualified personnel onlyTupleThe Tuple line is used only for fields within variable length m

Strona 21 - Included Xanbus cable

System Logging4–10 975-0720-01-01This manual is for use by qualified personnel only

Strona 22 - Conext XW SCP

975-0720-01-01 5–1This manual is for use by qualified personnel only5 Upgrading FirmwareChapter 5, “Upgrading Firmware” contains information about upg

Strona 23

Upgrading Firmware5–2 975-0720-01-01This manual is for use by qualified personnel onlyIntroductionThe firmware upgrade feature allows Conext Configura

Strona 24

975-0720-01-01 1–1This manual is for use by qualified personnel only1 Introduction and InstallationChapter 1, “Introduction and Installation” introduc

Strona 25

Starting Firmware Upgrade975-0720-01-01 5–3This manual is for use by qualified personnel onlyTo upgrade Conext Configuration Tool firmware:1. Power do

Strona 26 - USB-to-Xanbus Adapter Status

Upgrading Firmware5–4 975-0720-01-01This manual is for use by qualified personnel onlyAfter clicking Upgrade, progress bars for each device will be di

Strona 27

975-0720-01-01 A–1This manual is for use by qualified personnel onlyA Legacy USB-to-Xanbus AdaptersAppendix A, “Legacy USB-to-Xanbus Adapters” provid

Strona 28 - Control Menu Features

Legacy USB-to-Xanbus AdaptersA–2 975-0720-01-01This manual is for use by qualified personnel onlyInstalling Previous Versions of the USB-to-Xanbus Ada

Strona 29 - Configure Menu Features

Installing Previous Versions of the USB-to-Xanbus Adapter975-0720-01-01 A–3This manual is for use by qualified personnel onlyWindows XPTo install usin

Strona 30 - Temperature Units

Legacy USB-to-Xanbus AdaptersA–4 975-0720-01-01This manual is for use by qualified personnel only3. Select Search for the best driver in these locatio

Strona 31 - Restore Configuration

Installing Previous Versions of the USB-to-Xanbus Adapter975-0720-01-01 A–5This manual is for use by qualified personnel only3. Click on the Start but

Strona 32 - View Menu Functions

Legacy USB-to-Xanbus AdaptersA–6 975-0720-01-01This manual is for use by qualified personnel onlyWindows 8To install using Windows 8:1. Open the Charm

Strona 33 - 1–22 975-0720-01-01

Installing Previous Versions of the USB-to-Xanbus Adapter975-0720-01-01 A–7This manual is for use by qualified personnel only2. Click the Update and R

Strona 34 - 2 System

Legacy USB-to-Xanbus AdaptersA–8 975-0720-01-01This manual is for use by qualified personnel only4. Click Advanced Options, followed by Windows Startu

Strona 35

Introduction and Installation1–2 975-0720-01-01This manual is for use by qualified personnel onlyIntroducing Conext Configuration ToolConext Configura

Strona 36

Printed in ChinaSchneider Electricwww.SEsolar.com For other country details please contact your local Schneider Electric Sales Representative or visit

Strona 37 - Quick Configuration Method

Introducing Conext Configuration Tool975-0720-01-01 1–3This manual is for use by qualified personnel onlyInside the BoxThe following items are include

Strona 38

Introduction and Installation1–4 975-0720-01-01This manual is for use by qualified personnel only❐ Xanbus network cable (14 ft./4.25 m)❐ Installation

Strona 39

Installing Conext Configuration Tool975-0720-01-01 1–5This manual is for use by qualified personnel onlyInstalling Conext Configuration ToolTo install

Strona 40

Introduction and Installation1–6 975-0720-01-01This manual is for use by qualified personnel onlyConnecting the USB-to-Xanbus Adapter to Your Computer

Strona 41

Installing Conext Configuration Tool975-0720-01-01 1–7This manual is for use by qualified personnel only3. Under Device Type, select USB.4. Click OK.T

Strona 42

Introduction and Installation1–8 975-0720-01-01This manual is for use by qualified personnel only6. The internal serial number of the USB-to-Xanbus ad

Strona 43

Copyright and ContactCopyright © 2012, 2014 Schneider Electric. All Rights Reserved.All trademarks are owned by Schneider Electric Industries SAS or i

Strona 44

Installing Conext Configuration Tool975-0720-01-01 1–9This manual is for use by qualified personnel onlyConnecting the USB-to-Xanbus Adapter to the Xa

Strona 45

Introduction and Installation1–10 975-0720-01-01This manual is for use by qualified personnel onlyNote: Ensure that the USB-to-Xanbus adapter pins are

Strona 46

Installing Conext Configuration Tool975-0720-01-01 1–11This manual is for use by qualified personnel onlyNetwork terminationThe Xanbus network must be

Strona 47

Introduction and Installation1–12 975-0720-01-01This manual is for use by qualified personnel onlyInstalling the Conext Configuration Tool SoftwareTo

Strona 48 - Detailed Configuration Method

Installing Conext Configuration Tool975-0720-01-01 1–13This manual is for use by qualified personnel only7. Add a desktop icon by clicking on the appr

Strona 49

Introduction and Installation1–14 975-0720-01-01This manual is for use by qualified personnel only11. An information screen appears, as shown below.To

Strona 50

Operating Conext Configuration Tool975-0720-01-01 1–15This manual is for use by qualified personnel onlyOperating Conext Configuration ToolUSB-to-Xanb

Strona 51

Introduction and Installation1–16 975-0720-01-01This manual is for use by qualified personnel only3. Configure the Conext Automatic Generator Start. S

Strona 52

Operating Conext Configuration Tool975-0720-01-01 1–17This manual is for use by qualified personnel only•Perform Firmware Upgrades• Convert Phase of y

Strona 53

Introduction and Installation1–18 975-0720-01-01This manual is for use by qualified personnel onlyChargeUse this feature to enable or disable charging

Strona 54

About This Guide975-0720-01-01 iiiThis manual is for use by qualified personnel onlyAbout This GuidePurposeThe purpose of this Owner’s Guide is to pro

Strona 55

Operating Conext Configuration Tool975-0720-01-01 1–19This manual is for use by qualified personnel only3. To read the current names, click the Read b

Strona 56

Introduction and Installation1–20 975-0720-01-01This manual is for use by qualified personnel onlyFirmware UpgradeTo upgrade the firmware in a device,

Strona 57

Operating Conext Configuration Tool975-0720-01-01 1–21This manual is for use by qualified personnel onlyView Menu FunctionsSystem MapTo view the Syste

Strona 58

Introduction and Installation1–22 975-0720-01-01This manual is for use by qualified personnel only

Strona 59

975-0720-01-01 2–1This manual is for use by qualified personnel only2 System ConfigurationChapter 2 contains information and procedures to configure a

Strona 60

System Configuration2–2 975-0720-01-01This manual is for use by qualified personnel onlyAbout the Configuration WizardsThe Conext Configuration Tool C

Strona 61

Using the Configuration Wizard975-0720-01-01 2–3This manual is for use by qualified personnel onlyUsing the Configuration Wizard1. Start the Configura

Strona 62

System Configuration2–4 975-0720-01-01This manual is for use by qualified personnel onlyQuick Configuration Method1. Reset devices to factory defaults

Strona 63

Using the Configuration Wizard975-0720-01-01 2–5This manual is for use by qualified personnel onlyIf possible, take note of which units are assigned w

Strona 64 - Restoring a Configuration

System Configuration2–6 975-0720-01-01This manual is for use by qualified personnel onlySetting the connections for a Xanbus-enabled device provides a

Strona 65

About This Guideiv 975-0720-01-01This manual is for use by qualified personnel onlyChapter 3, “Device Configuration” describes how to use Conext Confi

Strona 66 - 3 Device

Using the Configuration Wizard975-0720-01-01 2–7This manual is for use by qualified personnel onlyTo configure a single-phase unit in a single-phase c

Strona 67 - Configuring Devices

System Configuration2–8 975-0720-01-01This manual is for use by qualified personnel onlyConfiguring Split Phase Master and Slave DevicesIf you chose t

Strona 68 - Configuration Commands

Using the Configuration Wizard975-0720-01-01 2–9This manual is for use by qualified personnel onlyf) When selection is finished, click Next. Proceed t

Strona 69 - OF ELECTRIC SHOCK OR FIRE

System Configuration2–10 975-0720-01-01This manual is for use by qualified personnel onlyi) When selection is finished, click Next. Proceed to Set the

Strona 70

Using the Configuration Wizard975-0720-01-01 2–11This manual is for use by qualified personnel only6. Set the Conext XW Inverter/Charger Custom Batter

Strona 71 - Inverter Configuration

System Configuration2–12 975-0720-01-01This manual is for use by qualified personnel onlyTable 2-2 XW Inverter/Charger Custom Battery SettingsSetting

Strona 72

Using the Configuration Wizard975-0720-01-01 2–13This manual is for use by qualified personnel only7. Set the Solar Charge Controller Charger Settings

Strona 73 - Charger Configuration

System Configuration2–14 975-0720-01-01This manual is for use by qualified personnel only8. Set the Solar Charge Controller Custom Battery Settings. (

Strona 74

Using the Configuration Wizard975-0720-01-01 2–15This manual is for use by qualified personnel only9. Save the System Configuration.If necessary, you

Strona 75 - AC Transfer Configuration

System Configuration2–16 975-0720-01-01This manual is for use by qualified personnel onlyThe network requires that each device of the same type have a

Strona 76

Safety975-0720-01-01 vThis manual is for use by qualified personnel onlyImportant Safety InstructionsREAD AND SAVE THESE INSTRUCTIONS - DO NOT DISCAR

Strona 77 - Grid Tie Configuration

Using the Configuration Wizard975-0720-01-01 2–17This manual is for use by qualified personnel only3. Set the AC and DC connections for all devices.Se

Strona 78

System Configuration2–18 975-0720-01-01This manual is for use by qualified personnel only5. Set the XW Inverter/Charger Inverter Settings.Figure 2-20

Strona 79

Using the Configuration Wizard975-0720-01-01 2–19This manual is for use by qualified personnel only6. Set the XW Inverter/Charger Settings.Figure 2-21

Strona 80

System Configuration2–20 975-0720-01-01This manual is for use by qualified personnel only7. Set the Conext XW+ Inverter/Charger Custom Battery Setting

Strona 81

Using the Configuration Wizard975-0720-01-01 2–21This manual is for use by qualified personnel only8. Set the XW Inverter/Charger AC Settings.AC Setti

Strona 82

System Configuration2–22 975-0720-01-01This manual is for use by qualified personnel only9. Set the XW Inverter/Charger Grid Support Settings.The Grid

Strona 83 - 3–18 975-0720-01-01

Using the Configuration Wizard975-0720-01-01 2–23This manual is for use by qualified personnel onlyFigure 2-25 Setting the XW Inverter/Charger Grid Su

Strona 84

System Configuration2–24 975-0720-01-01This manual is for use by qualified personnel only10. Set the XW Solar Charge Controller Charger settings.Load

Strona 85

Using the Configuration Wizard975-0720-01-01 2–25This manual is for use by qualified personnel only11. Set the XW Solar Charge Controller Custom Batte

Strona 86 - Solar Charge Controllers

System Configuration2–26 975-0720-01-01This manual is for use by qualified personnel only12. Set the XW Solar Charge Controller Input Settings.The inp

Strona 87

Safetyvi 975-0720-01-01 This manual is for use by qualified personnel onlySafety Information1. Before using the Conext SW/XW/XW+ inverter, read all in

Strona 88 - Thermal Status

Using the Configuration Wizard975-0720-01-01 2–27This manual is for use by qualified personnel onlyMulti-Cluster Configuration MethodTo configure a mu

Strona 89

System Configuration2–28 975-0720-01-01This manual is for use by qualified personnel onlyyou want to be the phase master into the master boxes for eac

Strona 90

Using the Configuration Wizard975-0720-01-01 2–29This manual is for use by qualified personnel only5. A Battery Cluster Warning will appear advising t

Strona 91 - Solar Input Configuration

System Configuration2–30 975-0720-01-01This manual is for use by qualified personnel only8. If Custom was selected as Battery Type, set the Conext XW

Strona 92 - Advanced Features

Restoring a Configuration975-0720-01-01 2–31This manual is for use by qualified personnel only10. Set the Conext XW+ AC Settings as outlined in Step 8

Strona 93

System Configuration2–32 975-0720-01-01This manual is for use by qualified personnel onlyFiles that appear in red are incompatible with your system. T

Strona 94 - Generator Configuration

975-0720-01-01 3–1This manual is for use by qualified personnel only3 Device ConfigurationChapter 3, “Device Configuration” describes how to use Conex

Strona 95

Device Configuration3–2 975-0720-01-01This manual is for use by qualified personnel onlyConfiguring DevicesYou can use Conext Configuration Tool to co

Strona 96 - Trigger Configuration

Configuring Devices975-0720-01-01 3–3This manual is for use by qualified personnel onlyConfiguration CommandsEvery configuration dialog box includes t

Strona 97

Device Configuration3–4 975-0720-01-01This manual is for use by qualified personnel onlySaving the System ConfigurationYou can save the current system

Strona 98 - Multi-Unit AGS Configuration

Safety975-0720-01-01 viiThis manual is for use by qualified personnel onlyDANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Apply appropriate

Strona 99

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–5This manual is for use by qualified personnel onlyThe following setting catego

Strona 100 - Basic Configuration

Device Configuration3–6 975-0720-01-01This manual is for use by qualified personnel onlyInverter ConfigurationInverter configuration includes enabling

Strona 101

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–7This manual is for use by qualified personnel onlyTable 3-1 Inverter Settings

Strona 102 - Basic Status

Device Configuration3–8 975-0720-01-01This manual is for use by qualified personnel onlyCharger ConfigurationCharger Configuration gives you options f

Strona 103 - Battery Configuration

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–9This manual is for use by qualified personnel onlyBattery ConfigurationBattery

Strona 104

Device Configuration3–10 975-0720-01-01This manual is for use by qualified personnel onlyAC Transfer ConfigurationAC Transfer configures the voltage a

Strona 105

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–11This manual is for use by qualified personnel onlyFigure 3-9 Inverter/Charger

Strona 106 - Multi-Unit Configuration

Device Configuration3–12 975-0720-01-01This manual is for use by qualified personnel onlyGrid Tie ConfigurationThe Grid Tie Configuration window sets

Strona 107 - Modbus Configuration

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–13This manual is for use by qualified personnel onlyFigure 3-10 Inverter/Charge

Strona 108

Device Configuration3–14 975-0720-01-01This manual is for use by qualified personnel onlyGenerator Support ConfigurationConext XW+ only: Generator sup

Strona 109 - Getting Started

Safetyviii 975-0720-01-01 This manual is for use by qualified personnel onlyDANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Battery Circuit B

Strona 110 - Configuration

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–15This manual is for use by qualified personnel onlyGenerators have a limited o

Strona 111 - Automatic restart

Device Configuration3–16 975-0720-01-01This manual is for use by qualified personnel onlyFigure 3-12 XW Inverter/Charger Auxiliary Output Configuratio

Strona 112 - Email Options

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–17This manual is for use by qualified personnel onlyFigure 3-13 XW Inverter/Cha

Strona 113

Device Configuration3–18 975-0720-01-01This manual is for use by qualified personnel onlyFigure 3-15 XW Inverter/Charger Auxiliary Output Configuratio

Strona 114 - Running the Logger

Configuring Conext XW+ and Conext SW Inverter/Chargers975-0720-01-01 3–19This manual is for use by qualified personnel onlyMulti-Unit ConfigurationMul

Strona 115 - Using the Data

Device Configuration3–20 975-0720-01-01This manual is for use by qualified personnel onlyAdvanced Features ConfigurationAdvanced Features Configuratio

Strona 116 - Date and Time

Configuring Conext MPPT 80 600 and Conext MPPT 60 150 Solar Charge Controllers975-0720-01-01 3–21This manual is for use by qualified personnel onlySav

Strona 117 - 4–10 975-0720-01-01

Device Configuration3–22 975-0720-01-01This manual is for use by qualified personnel onlyBasic StatusThe Basic Status window displays input and output

Strona 118 - 5 Upgrading

Configuring Conext MPPT 80 600 and Conext MPPT 60 150 Solar Charge Controllers975-0720-01-01 3–23This manual is for use by qualified personnel onlyThe

Strona 119 - Starting Firmware Upgrade

Device Configuration3–24 975-0720-01-01This manual is for use by qualified personnel onlyCharger ConfigurationCharger Configuration gives you options

Strona 120

Contents975-0720-01-01 ixThis manual is for use by qualified personnel only1 Introduction and InstallationIntroducing Conext Configuration Tool - - -

Strona 121 - Upgrade Failures

Configuring Conext MPPT 80 600 and Conext MPPT 60 150 Solar Charge Controllers975-0720-01-01 3–25This manual is for use by qualified personnel onlyFig

Strona 122 - A Legacy USB-to

Device Configuration3–26 975-0720-01-01This manual is for use by qualified personnel onlySolar Input ConfigurationSolar Input Configuration allows you

Strona 123 - USB-to-Xanbus adapter drivers

Configuring Conext MPPT 80 600 and Conext MPPT 60 150 Solar Charge Controllers975-0720-01-01 3–27This manual is for use by qualified personnel onlyAdv

Strona 124 - Windows XP

Device Configuration3–28 975-0720-01-01This manual is for use by qualified personnel onlyConfiguring the Conext Automatic Generator StartThe following

Strona 125 - Windows 7

Configuring the Conext Automatic Generator Start975-0720-01-01 3–29This manual is for use by qualified personnel onlyGenerator ConfigurationGenerator

Strona 126

Device Configuration3–30 975-0720-01-01This manual is for use by qualified personnel onlyExercise Time Sets the time of day that the AGS exercises the

Strona 127 - Windows 8

Configuring the Conext Automatic Generator Start975-0720-01-01 3–31This manual is for use by qualified personnel onlyTrigger ConfigurationTrigger Conf

Strona 128

Device Configuration3–32 975-0720-01-01This manual is for use by qualified personnel onlyLow Battery Voltage Start(24 hr)Enables the AGS to start the

Strona 129

Configuring the Conext Automatic Generator Start975-0720-01-01 3–33This manual is for use by qualified personnel onlyMulti-Unit AGS ConfigurationAGS B

Strona 130 - Schneider Electric

Device Configuration3–34 975-0720-01-01This manual is for use by qualified personnel onlySaving and Restoring ConfigurationsSave Configuration allows

Komentarze do niniejszej Instrukcji